Zenition 30

Mobile C-arm with Flat Detector

尋找類似產品

Give your surgical teams simple, more flexible imaging to make fast, informed decisions with the Philips Image Guided Therapy Mobile C-arm System 3000 – Zenition 30. Flat Detector technology along with advanced imaging algorithms and a Personalized IQ feature provide outstanding image quality and dose efficiency, Unique Surgeon Control and the Touch Screen Module empower end users by giving more control, while the Electromagnetic brakes reduce manual effort.

技術指標

X-ray generation
X-ray generation
X-ray generator
  • Monoblock 40 kHz high frequency generator
X-ray tube
  • Fixed Anode (tube)
Maximum generator output
  • 2.1 kW or 4 kW
Flat detector
Flat detector
Flat detector
  • Trixell amorphous silicon detector
Matrix size
  • FD11: 1024 x 1024 pixels
Detector Area
  • FD11: 20 cm x 20 cm (7.9" x 7.9")
Pixel pitch
  • 200 μm
Connectivity
Connectivity
Digital video out (optional)
  • 2 DVI connectors left and right monitor
USB storage
  • PNG, MP4, BMP
Wireless data transfer
  • Standard
Video in (optional)
  • S-Video, DVI (digital and analog), SDI
Advanced DICOM/IHE package⁵
  • Modality Worklist Mgmt, Modality Performed Procedure Step, Storage Commit
Options
Options
Image Viewer
  • Multi-Modality Viewer
Tank laser aiming device
  • Laser aimer projects a X-hair from the X-ray tank towards the Flat Detector
Flat detector laser aiming device
  • Laser aimer projects a crosshair from the detector towards the X-ray tank
Surgeon control⁵
  • Electromagnetic brake buttons on the detector
Geometry
Geometry
C-arc
  • Color coded, fully counterbalanced C-arc
C-arc depth
  • 73 cm / 29"
Source Image Distance
  • 100 cm / 39.4"
Angulation
  • 156° rotation (+90° / -66°)
Lowest lateral position
  • 106 cm / 41.7"
Free space in C-arm
  • 765 mm / 30.1"
X-ray generation
X-ray generation
X-ray generator
  • Monoblock 40 kHz high frequency generator
X-ray tube
  • Fixed Anode (tube)
Flat detector
Flat detector
Flat detector
  • Trixell amorphous silicon detector
Matrix size
  • FD11: 1024 x 1024 pixels
See all specifications
X-ray generation
X-ray generation
X-ray generator
  • Monoblock 40 kHz high frequency generator
X-ray tube
  • Fixed Anode (tube)
Maximum generator output
  • 2.1 kW or 4 kW
Flat detector
Flat detector
Flat detector
  • Trixell amorphous silicon detector
Matrix size
  • FD11: 1024 x 1024 pixels
Detector Area
  • FD11: 20 cm x 20 cm (7.9" x 7.9")
Pixel pitch
  • 200 μm
Connectivity
Connectivity
Digital video out (optional)
  • 2 DVI connectors left and right monitor
USB storage
  • PNG, MP4, BMP
Wireless data transfer
  • Standard
Video in (optional)
  • S-Video, DVI (digital and analog), SDI
Advanced DICOM/IHE package⁵
  • Modality Worklist Mgmt, Modality Performed Procedure Step, Storage Commit
Options
Options
Image Viewer
  • Multi-Modality Viewer
Tank laser aiming device
  • Laser aimer projects a X-hair from the X-ray tank towards the Flat Detector
Flat detector laser aiming device
  • Laser aimer projects a crosshair from the detector towards the X-ray tank
Surgeon control⁵
  • Electromagnetic brake buttons on the detector
Geometry
Geometry
C-arc
  • Color coded, fully counterbalanced C-arc
C-arc depth
  • 73 cm / 29"
Source Image Distance
  • 100 cm / 39.4"
Angulation
  • 156° rotation (+90° / -66°)
Lowest lateral position
  • 106 cm / 41.7"
Free space in C-arm
  • 765 mm / 30.1"
  • Zenition mobile C-arm systems are available for sale in a limited number of countries. Please check with your local representative for availability in your market.
  • Actual product representation may vary.
  • 1. Results obtained during claims substantiation study performed in February and September 2022 by Use-Lab GmbH, an independent company. Response is based on 42 respondents (26 surgeons & radiologists and 16 technologists & nurses) from the EU and US, who answered a questionnaire subsequent to a usability study with additional hands-on time with the system.
  • 2. Results obtained during claims substantiation study performed in February and September 2022 by Use-Lab GmbH, an independent company. Response is based on 37 respondents (26 surgeons & radiologists and 11 technologists & nurses) from the EU and US, who answered a questionnaire subsequent to a usability study with additional hands-on time with the system.
  • 3. Results obtained during claims substantiation study performed in February and September 2022 by Use-Lab GmbH, an independent company. Response is based on 50 respondents (26 surgeons & radiologists and 24 technologists & nurses) from the EU and US, who answered a questionnaire subsequent to a usability study with additional hands-on time with the system.
  • 4. The X-ray dose reductions refer to specific features and will vary depending on the dose parameters selected.
  • 5. Optional for 2.1 kW configuration and standard for 4 kW configuration.