Respironics Respiratory profile monitor

Respironics NM3

Respiratory profile monitor

尋找類似產品

The Respironics NM3 monitors physiologic gas exchange, deadspace, and alveolar tidal volume, and a host of accessory parameters. This valuable insight helps you answer the toughest clinical questions, throughout the continuum of care.

特點
Advanced monitoring

Advanced monitoring to improve ventilation

The Respironics NM3 non-invasively monitors volumetric (VCO2) and end-tidal (EtCO2) capnography. Clinicians can use this information to minimize the duration of mechanical ventilation and optimize the potential for successful extubation when managing critically ill patients.
Mainstream and sidestream CO2 monitoring

Mainstream and sidestream CO2 monitoring for all patients

This system provides mainstream or sidestream CO2 monitoring for intubated and non-intubated patients.
Interface with V200

Interface with V200 enriches data collection

This system has a direct interface with the V200 ventilator to expand data collection and display.
VentAssist option

VentAssist option provides real-time guidance and advice

VentAssist supports lung protective strategies for adult patients by providing an intuitive representation of patient status and advice on ventilation settings. Clinicians receive guidance based on six key parameters. They have the peace of mind that their patients are appropriately supported and a sense of control that an open loop system will not change settings.
Portable and adaptable

Portable and adaptable monitoring

The portable and adaptable monitoring, on and off conventional ventilators.
  • Advanced monitoring
  • Mainstream and sidestream CO2 monitoring
  • Interface with V200
  • VentAssist option
See all features
Advanced monitoring

Advanced monitoring to improve ventilation

The Respironics NM3 non-invasively monitors volumetric (VCO2) and end-tidal (EtCO2) capnography. Clinicians can use this information to minimize the duration of mechanical ventilation and optimize the potential for successful extubation when managing critically ill patients.
Mainstream and sidestream CO2 monitoring

Mainstream and sidestream CO2 monitoring for all patients

This system provides mainstream or sidestream CO2 monitoring for intubated and non-intubated patients.
Interface with V200

Interface with V200 enriches data collection

This system has a direct interface with the V200 ventilator to expand data collection and display.
VentAssist option

VentAssist option provides real-time guidance and advice

VentAssist supports lung protective strategies for adult patients by providing an intuitive representation of patient status and advice on ventilation settings. Clinicians receive guidance based on six key parameters. They have the peace of mind that their patients are appropriately supported and a sense of control that an open loop system will not change settings.
Portable and adaptable

Portable and adaptable monitoring

The portable and adaptable monitoring, on and off conventional ventilators.
Do you want to know what it means when products are certified for European Union Medical Device Regulations (EU MDR)?

技術指標

Alerts
Alerts
Nurse call
  • Normally opened and normally closed
Adjustable
  • ETCO2, SpO2, RR, no respiration, VCO2, pulse rate, cardiac output
Audio (adjustable volume)
  • 2 min, silence, or OFF
Visual
  • Screen indicator and alert bar with alarm priority
Communications
Communications
RS232
  • Yes
USB
  • Yes
Spacelabs Flexport
  • open interface
Analog output port
  • Yes
Philips VueLink
  • open interface
Printer capability
  • PCL3 and PCL5
Respi-Link
  • Yes
V200 interface
  • Yes
Operation
Operation
Cardiac output
  • NICO Sensor (option)
Pulse oximetry
  • Masimo sensors
Mainstream CO2
  • Capnostat 5 sensor
Sidestream CO2
  • LoFlo sensor (option)
Internal battery
Internal battery
Type
  • Lead acid gel cell
Recharge time
  • 12 hour(s)
Life
  • 45 minute(s)
Parameters measured
Parameters measured
mean airway pressure
  • MAP
Alveolar minute volume
  • Mvalv
Oxygen saturation
  • SpO2
Positive end expiratory pressure
  • PEEP
Minute volume
  • MV
Airway resistance
  • Raw
Peak inspiratory flow
  • PIF
Rapid shallow breathing index
  • I RSB
Respiration rate
  • RR
Dynamic compliance
  • Cdyn
Pulse rate
  • [heart symbol]
Peak expiratory pressure
  • PEP
Expired tidal volume
  • Vte
Peak expiratory flow
  • PEF
Peak inspiratory pressure
  • PIP
Inspired tidal volume
  • Vti
Airway deadspace
  • Vd Aw
CO2 elimination
  • VC02
End tidal carbon dioxide
  • ETCO2
Inspired carbon dioxide
  • Insp CO2
Deadspace to tidal volume ratio
  • Vd/Vt
Mixed expired CO2
  • PeCO2
Systematic vascular resistance
  • SVR
Patient types
Patient types
Neonatal
  • Yes
Adult
  • Yes
Pediatric
  • Yes
Cardiac output (option)
Cardiac output (option)
Stroke volume index
  • SVI
Cardiac index
  • CI
Stroke volume
  • SVR
Cardiac output
  • C.O.
Pulmonary capillary blood flow
  • PCBF
Alerts
Alerts
Nurse call
  • Normally opened and normally closed
Adjustable
  • ETCO2, SpO2, RR, no respiration, VCO2, pulse rate, cardiac output
Communications
Communications
RS232
  • Yes
USB
  • Yes
See all specifications
Alerts
Alerts
Nurse call
  • Normally opened and normally closed
Adjustable
  • ETCO2, SpO2, RR, no respiration, VCO2, pulse rate, cardiac output
Audio (adjustable volume)
  • 2 min, silence, or OFF
Visual
  • Screen indicator and alert bar with alarm priority
Communications
Communications
RS232
  • Yes
USB
  • Yes
Spacelabs Flexport
  • open interface
Analog output port
  • Yes
Philips VueLink
  • open interface
Printer capability
  • PCL3 and PCL5
Respi-Link
  • Yes
V200 interface
  • Yes
Operation
Operation
Cardiac output
  • NICO Sensor (option)
Pulse oximetry
  • Masimo sensors
Mainstream CO2
  • Capnostat 5 sensor
Sidestream CO2
  • LoFlo sensor (option)
Internal battery
Internal battery
Type
  • Lead acid gel cell
Recharge time
  • 12 hour(s)
Life
  • 45 minute(s)
Parameters measured
Parameters measured
mean airway pressure
  • MAP
Alveolar minute volume
  • Mvalv
Oxygen saturation
  • SpO2
Positive end expiratory pressure
  • PEEP
Minute volume
  • MV
Airway resistance
  • Raw
Peak inspiratory flow
  • PIF
Rapid shallow breathing index
  • I RSB
Respiration rate
  • RR
Dynamic compliance
  • Cdyn
Pulse rate
  • [heart symbol]
Peak expiratory pressure
  • PEP
Expired tidal volume
  • Vte
Peak expiratory flow
  • PEF
Peak inspiratory pressure
  • PIP
Inspired tidal volume
  • Vti
Airway deadspace
  • Vd Aw
CO2 elimination
  • VC02
End tidal carbon dioxide
  • ETCO2
Inspired carbon dioxide
  • Insp CO2
Deadspace to tidal volume ratio
  • Vd/Vt
Mixed expired CO2
  • PeCO2
Systematic vascular resistance
  • SVR
Patient types
Patient types
Neonatal
  • Yes
Adult
  • Yes
Pediatric
  • Yes
Cardiac output (option)
Cardiac output (option)
Stroke volume index
  • SVI
Cardiac index
  • CI
Stroke volume
  • SVR
Cardiac output
  • C.O.
Pulmonary capillary blood flow
  • PCBF

使用最新版 Microsoft Edge、Google Chrome 或 Firefox 瀏覽本網站效果最佳。